CareFusion Smoke Check Meter Dokumentacja Strona 1

Przeglądaj online lub pobierz Dokumentacja dla Wykrywacze dymu CareFusion Smoke Check Meter. CareFusion Smoke Check Meter Specifications Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj

Podsumowanie treści

Strona 1 - BabyCO Meter

 BabyCO Meter Operating Manual 

Strona 2

8 If the unit is switched on again too quickly after use there may be a response to residual expired carbon monoxide from the previous test. In thi

Strona 3

9 Note: the BabyCO meter should only be connected to a computer that is manufactured in accordance with EN60950 1992/1993 – ‘Safety of Information Te

Strona 4 - Introduction

10 The plastic tubing supplied with the gas should be pushed firmly over the reducing connector. Slowly turn the control knob anti-clockwise until t

Strona 5 - Cigarette Consumption

11 the meter does not read 20ppm use the calibration tool to push the calibration switch. The unit will then beep 3 times, store the new calibration

Strona 6

12 Sensor life ranges from 2 to 5 years and depends upon both the amount of exposure to CO and other gases, particularly solvents such as alcohol and

Strona 7 - Package Contents

13 Battery Life Battery life is approximately 30 hours of continuous use. When the battery has approximately 1 hour of useful life left the alarm wil

Strona 8 - Operation

14 When this occurs, the BabyCO meter must be returned to CareFusion, or an authorised agent, for battery replacement. Cleaning The mouthpiece adapte

Strona 9

15 Consumables / Supporting Products Cat. No. Description 36-PSA1200 22mm disposable cardboard mouthpieces (250 per box) 36-PSA2000 22mm mout

Strona 10 - PC Connection

16 Environment This instrument complies with directive EN60601-1-2 electromagnetic compatibility but can be affected by cellular phones and by electr

Strona 11 - Calibration

17 Dimensions 170 x 60 x 26 mm Display 3 ½ digit LCD Storage temperature -20° to +70 °C Storage humidity 30% to 90%

Strona 12

 

Strona 13

18 Customer contact information UK Customers only For all Sales Order processing for products, training and spare parts, Service and Technical Suppor

Strona 14

19 97204 Hoechberg Germany Customer Service Sales Enquiries: Telephone: 0049 931 4972 670 Email: [email protected] Factory

Strona 17 - Symbols

 CareFusion UK 232 Ltd., Quayside Chatham Maritime Kent ME4 4QY U.K. 0086 JDE no. 36-MAN1222 Drg no. 113-09 Issue 1.5 Febru

Strona 18 - Specifications

1 Contents Overview ... 2 Introduction ...

Strona 19 - Storage humidity 30% to 90%

2 Overview The BabyCO meter is a hand held battery operated device used to measure the concentration of carbon monoxide, CO, on the breath and calcul

Strona 20 - Customer contact information

3 Warning lights are provided to give an instant indication of the smoking level. The warning light levels are user adjustable when the unit is con

Strona 21

4 Please note that some urban areas may have high environmental levels of CO. This can cause a rise in exhaled CO of a few ppm above that which is n

Strona 22

5 Package Contents The BabyCO meter is supplied with a carrying case containing the following items: 1. BabyCO meter (Cat No. 36-BC01-STK) 2. 22 mm

Strona 23

6 Operation For accurate results the BabyCO meter should be used at room temperature. If the instrument has been stored in cool or hot conditions th

Strona 24 - © CareFusion 2010

7 COppmProvided the subject is not too distressed after seeing the breath CO measurement, then the calculated foetal carboxyhemaglobin level may be

Komentarze do niniejszej Instrukcji

Brak uwag